JCJ300A temperature and humidity measuring instrument
JCJ300A Temperature and Humidity Measuring Instrument
Product introduction:
JCJ300A temperature and humidity measuring instrument, with anti-interference design of linearized processing circuit, Jiu Chunjian@ instrument can receive the output signal of JCJ100/200 series temperature and humidity transmitter, the instrument and transmitter form a set of temperature and humidity measuring instrument. JCJ300A temperature and humidity measuring instrument has the characteristics of high measurement accuracy and stable performance.
Application:
JUCSAN@Instrument series: JCJ300A temperature and humidity measuring instrument is suitable for industrial automation measurement, environmental monitoring, intelligent building, electric power, petrochemical, medical and health and other places that require temperature and humidity measurement.
technical parameter
JCJ300A |
humidity | temperature |
basic error | Less than 0.2%F.S | |
Resolution |
0.1 %RH |
0.1℃ |
Display range |
0~100 |
-999~1999 |
input signal |
1、0~5V 2、0~10V 4、0~10mA 5、0~20mA |
|
Display method | Bright red LED displays 3 digits of humidity and 4 digits of temperature | |
LED word height |
15×8mm |
|
powered by |
220VAC±10% 50Hz/60Hz |
|
feed | DC 12VDC/30mA or 24 VDC /30mA | |
working environment | Temperature: -10~55℃ Humidity: <90%RH | |
power consumption |
<4W |
|
shell | ABS black 160×80×78mm Hole size: 152×76mm |
|
Installation method | Dial mount or other |
product model:
JCJ300A temperature and humidity measuring instrumentmodel | Type spectrum | ||||
JCJ300A | S port P port | ||||
|
S port |
|
|||
|
1 |
0~5VDC (default) | |||
2 |
0~10VDC |
||||
3 |
4~20mA |
||||
4 |
0~10mA/20mA |
||||
5 |
Other please specify | ||||
|
P port | Working power | |||
|
1 |
220VAC(default) |
|||
2 |
24VDC |
||||
3 |
24VAC |
||||
4 |
12VDC |
||||
5 |
12VAC |
Selection description: |
|
|
1. Indicate the temperature display range 2. If the instrument needs to provide the transmitter power supply (feed output), please indicate: 12VDC or 24VDC (the precondition is The working power of the instrument is 220VAC), and the instrument has no feed output by default. 3. Special function requirements can be customized. |
Online Message
If you are interested in us, welcome your message, we will reply you in time!
contact us
Scan it
Follow us
Copyright © 2021 Nanjing Tansuo Optoelectronics Co., Ltd. All rights reserved Powered by: www.300.cn | 苏ICP备07006102号-1